Mostrar registro simples

dc.contributor.authorSilva, Claudia da Costapt_BR
dc.contributor.authorAlves, Marta Maria Osóriopt_BR
dc.contributor.authorEl Halal, Michel Georges dos Santospt_BR
dc.contributor.authorPinheiro, Sabrina dos Santospt_BR
dc.contributor.authorCarvalho, Paulo Roberto Antonaccipt_BR
dc.date.accessioned2014-08-27T02:11:32Zpt_BR
dc.date.issued2013pt_BR
dc.identifier.issn0103-507Xpt_BR
dc.identifier.urihttp://hdl.handle.net/10183/101956pt_BR
dc.description.abstractObjetivo: Comparar os escores resultantes da escala Comfort-B com o índice biespectral, em crianças de uma unidade de terapia intensiva. Métodos: Onze crianças com idades entre 1 mês e 16 anos, submetidas a ventilação mecânica e sedação, foram classificadas pelo índice biespectral e pela escala Comfort-B, simultaneamente. Foi obtido registro de seus comportamentos por filmagem digital; posteriormente tal registro foi avaliado por três observadores independentes e foram aplicados testes de concordância (Bland-Altman e Kappa). Foi testada a correlação entre os dois métodos (correlação de Pearson). Resultados: Foram realizadas 35 observações em 11 pacientes. A concordância entre os avaliadores, segundo o coeficiente de Kappa, variou de 0,56 a 0,75 (p<0,001). Houve associação positiva e regular entre índice biespectral e Comfort-B, com r=0,424 (p=0,011) até r=0,498 (p=0,002). Conclusão: Devido à alta concordância entre os avaliadores independentes e a correlação regular entre os dois métodos, conclui-se que a escala Comfort-B é reprodutível e útil na classificação do nível de sedação de crianças em ventilação mecânica.pt_BR
dc.description.abstractObjective: Compare the scores resulting from the Comfort-B scale with the bispectral index in children in an intensive care unit. Methods: Eleven children between the ages of 1 month and 16 years requiring mechanical ventilation and sedation were simultaneously classified based on the bispectral index and the Comfort-B scale. Their behavior was recorded using digital photography, and the record was later evaluated by three independent evaluators. Agreement tests (Bland-Altman and Kappa) were then performed. The correlation between the two methods (Pearson correlation) was tested. Results: In total, 35 observations were performed on 11 patients. Based on the Kappa coefficient, the agreement among evaluators ranged from 0.56 to 0.75 (p<0.001). There was a positive and consistent association between the bispectral index and the Comfort-B scale [r=0.424 (p=0.011) to r=0.498 (p=0.002)]. Conclusion: Due to the strong correlation between the independent evaluators and the consistent correlation between the two methods, the results suggest that the Comfort-B scale is reproducible and useful in classifying the level of sedation in children requiring mechanical ventilation.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista brasileira de terapia intensiva. Rio de Janeiro. Vol. 25, n. 4 (out./dez. 2013), p. 306-311.pt_BR
dc.rightsOpen Accessen
dc.subjectRespirationen
dc.subjectRespiração artificialpt_BR
dc.subjectArtificial/methodsen
dc.subjectMonitorização fisiológicapt_BR
dc.subjectInstrumentaçãopt_BR
dc.subjectMonitoringen
dc.subjectPhysiologic/instrumentationen
dc.subjectSedação conscientept_BR
dc.subjectConscious sedationen
dc.subjectEletroencefalografiapt_BR
dc.subjectElectroencephalography/instrumentationen
dc.subjectCriançapt_BR
dc.subjectUnidades de terapia intensiva pediátricapt_BR
dc.subjectChilden
dc.subjectIntensive care unitsen
dc.subjectPediatricen
dc.titleComparação dos níveis de sedação graduados pela escala Comfort-B e pelo índice biespectral de crianças em ventilação mecânica na unidade de terapia intensiva pediátricapt_BR
dc.title.alternativeA comparison of gradual sedation levels using the Comfort-B scale and bispectral index in children on mechanical ventilation in the pediatric intensive care unit en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000921613pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples