dc.description.abstractO presente trabalho é um estudo experimental do comportamento térmico de dois tipos de coberturas planas: cobertura verde e terraço. Através do monitoramento de uma bancada experimental, construída na cidade de Pelotas, RS, foram obtidos conjuntos de dados relativos a períodos de uma semana, sendo uma em período de verão e a outra no inverno. São descritos a bancada experimental e os métodos usados, assim como apresentados os sensores e equipamentos empregados. Na análise do desempenho térmico foram comparadas as temperaturas superficiais obtidas em três camadas diferentes de cada cobertura, bem como os dados de temperatura do ar, registrados no exterior e no interior da bancada, em câmaras sob as coberturas em estudo. Quanto às temperaturas superficiais, a externa, registrada na cobertura verde, apresentou menor amplitude de variação, nos dois períodos analisados; a interna foi menor no verão, e praticamente igual à do terraço, no inverno. Quanto à temperatura do ar interno, no verão, a da cobertura verde foi sempre menor e, no inverno, em dias de frio mais intenso, ela tornou-se superior ou igual à temperatura interna no terraço. A cobertura verde apresentou maior capacidade de amortecer a onda térmica externa, e maior retardo térmico; além disso, todos os seus materiais constituintes sofreram menores oscilações de temperatura.pt_BR
dc.description.abstractThe present work compares the thermal behaviour of a traditional flat roof with that of a flat green roof. An experimental work was developed by means of the monitoring of the two types of roof during a summer and a winter period of one week. The work describes the experimental setting as well as the methods and equipment used. The thermal assessment was made through the comparison of the temperatures of three layers of each of the roofs, that were also compared to the external temperature and to the indoor temperature below the roof. Both in summer and in winter the surface temperature on the top of the green roof was the one with lowest amplitude range. The surface temperature under the green roof was the lowest during the summer and almost equal to the one under the traditional flat roof during the winter. In summertime, again the indoor temperature under the green roof was always below that under the other roof. The same happened during most of the winter, being above the indoor temperature of the traditional roof only on the coldest days. The green roof showed a higher time delay and a higher decrement factor and all its components showed a smaller temperature range.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDesempenho térmicopt_BR
dc.subjectCoberturas verdespt_BR
dc.titleEstudo experimental do desempenho térmico de coberturas planaspt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000248241pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programCurso de Pós-Graduação em Engenharia Civilpt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date1998pt_BR