Mostrar registro simples

dc.contributor.advisorBarros, Sérgio Estelita Cavalcantept_BR
dc.contributor.authorJaramillo, Katherine Estefanía Cevallospt_BR
dc.date.accessioned2022-08-05T04:44:10Zpt_BR
dc.date.issued2018pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/246211pt_BR
dc.description.abstractObjetivo: Avaliar os efeitos do cantilever torqueado (CT) e convencional (CC), feitos de aço inoxidável (SS) e liga de titânio molibdénio (TMA), na verticalização de molares inferiores impactados mesialmente, utilizando análise tridimensional de elementos finitos. Métodos: O modelo tridimensional mandibular incluiu: parte da mandíbula com o segundo molar inferior impactado e inclinado mesialmente, ligamento periodontal (LP), tubo molar, mini-implante e cantilevers. Quatro modelos de método de elementos finitos (CT-SS, CTTMA, CC-SS e CC-TMA) foram criados para simular diferentes mecânicas de verticalização ancoradas esqueleticamente. A mecânica de CC envolveu um cantilever helicoidal conhecido (0,019 x 0,025"), agindo sobre um tubo molar na face vestibular. A mecânica CT incluía um cantilever torqueado (0,019" x 0,025") capaz de produzir torque mesial de raiz por atuar sobre um tubo posicionado na superfície ocluso-distal do molar, com o slot na direção vestíbulolingual. O deslocamento tridimensional do molar e a distribuição de tensão no LP deste dente foram registrados. Resultados: O cantilever SS produziu quase o dobro do deslocamento molar quando comparado ao cantilever TMA. A mecânica CT mostrou um deslocamento mesial mais evidente dos ápices da raiz do molar. A mecânica CC teve maior rotação do molar. O momento de verticalização do CT produziu maior extrusão mesial molar, bem como maior intrusão do ápice distal da raiz deste dente. O sistema de deflexão dupla da mecânica do CT induziu uma menor tensão no LP, independentemente da liga metálica. Conclusões: O cantilever torqueado proporcionou um momento de verticalização do molar mais eficiente e com menos movimento dentário indesejado e tensão no LP, bem como um local mais acessível para a colagem do tubo molar.pt_BR
dc.description.abstractObjective: To evaluate the effects of the torqued cantilever (TC) and conventional tipback cantilever (CC) made of stainless steel (SS) and titanium-molybdenum alloy (TMA) on the uprighting of mesially impacted mandibular molars using three-dimensional finite element analysis. Methods: The three-dimensional mandibular model included part of the mandible with mesially tipped and impacted mandibular second molar, periodontal ligament (PDL), molar tube, mini-implant, and cantilevers. Four finite element method models (TC-SS, TCTMA, CC-SS, and CC-TMA) were created to simulate different skeletally anchored uprighting mechanics. CC mechanics involved a known 0.019 X 0.025-in helical cantilever acting on a buccal molar tube. TC mechanics included a 0.019 X 0.025-in cantilever capable of producing mesial root torque by acting on a tube positioned on the molar disto-occlusal surface with the slot in buccolingual direction. Three-dimensional molar displacement and stress distribution on the molar PDL were recorded. Results: The SS cantilever produced almost twice as much molar displacement as the TMA. TC mechanics showed more evident mesial displacement of the molar root apexes. CC mechanics had greater molar rotation. TC uprighting moment produced greater molar mesial extrusion as well as greater intrusion of the distal root apex. The dual deflection system of the TC mechanics induced the lowest stress on the PDL, regardless the of metallic alloy. Conclusions: Torqued cantilever delivered a more efficient uprighting moment to the molar with less unwanted tooth movement and stress on the PDL, as well as a more accessible site for bonding the molar tube.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectOrthodonticsen
dc.subjectOrtodontiapt_BR
dc.subjectMolar uprightingen
dc.subjectTécnicas de movimentação dentáriapt_BR
dc.subjectAço inoxidávelpt_BR
dc.subjectTooth movementen
dc.subjectStainless steelen
dc.subjectTitanium molybdenumen
dc.subjectSecond molaren
dc.titleCantilever torqueado e convencional para verticalização do molar mesialmente impactado : análise 3d por elementos finitospt_BR
dc.title.alternativeTorqued and conventional cantilever for uprighting mesially impacted molars : a 3-d finite element analysisen
dc.typeDissertaçãopt_BR
dc.identifier.nrb001146840pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2022pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples