Mostrar registro simples

dc.contributor.authorLopes, Raynner Menezespt_BR
dc.contributor.authorBassegio, Pedro Guido Mottespt_BR
dc.contributor.authorCastiglio, Guilherme Santannapt_BR
dc.contributor.authorTeixeira, Thaise Daniele Paixãopt_BR
dc.contributor.authorKempka, Marianept_BR
dc.contributor.authorDai Prá, Mauríciopt_BR
dc.contributor.authorMarques, Marcelo Giulianpt_BR
dc.date.accessioned2023-12-01T03:25:54Zpt_BR
dc.date.issued2023pt_BR
dc.identifier.issn0101-6040pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/267870pt_BR
dc.description.abstractAs despesas com energia elétrica têm onerado os custos dos Sistemas de Bombeamento de Água (SBA) no Brasil. As ações de eficiência energética são utilizadas para reduzir essas despesas, permitindo um melhor planejamento das companhias de saneamentoe melhorias na manutenção e operação dos SBAs. No presente estudo foi utilizado um algoritmo de otimização para minimizar os custos operacionais e de implantação de 441 SBAs fictícios, com velocidade rotacional constante. Posteriormente, foram utilizados dois indicadores de desempenho operacional nos SBAs, sendo eles o Consumo Específico de Energia Elétrica Normalizado (CEEN) e o Fator de Carga (FC). Nos resultados, foram indicados pelo CEEN bons desempenhos operacionais nos SBAs. Para o FC, os desempenhos variaram de péssimo a regular. Essa característica é previsível e pode ser melhorada se o sistema for dimensionado e operado em etapas.pt_BR
dc.description.abstractElectricity expense has increased the cost of Water Pumping Systems (WPS) in Brazil. Energy efficiency actions are necessary to reduce these expenses, allowing for a better planning by the sanitation companies, as well as improvements in the maintenance and operation of the WPSs. In the present study, an optimization algorithm is used to minimize the operational and implementation costs of 441 fictitious WPSs, operating at constant rotational speed. Subsequently, two operational performance indicators were used in the SBAs, namely, the Standardized Energy Consumption (SEC) and the Load Factor (LF). In the results, the SEC indicated good operational performance in the WPSs. For the LF, performances ranged from poor to regular. This characteristic is predictable and can be improved if the system is constructed to be scaled and to operate in stages.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista DAE. Vol. 71, n. 240 (2023), p. 79-90pt_BR
dc.rightsOpen Accessen
dc.subjectAbastecimento de águapt_BR
dc.subjectWater supplyen
dc.subjectElectricityen
dc.subjectEnergia elétricapt_BR
dc.subjectEnergy efficiencyen
dc.subjectSistemas de bombeamentopt_BR
dc.subjectEficiência energéticapt_BR
dc.subjectCosten
dc.subjectCustopt_BR
dc.subjectGenetic algorithmen
dc.titleMetodologia para otimização operacional de sistema de bombeamento de água com velocidade rotacional constantept_BR
dc.title.alternativeMetodology for optimization of water pumping operational system at constant rotating speed en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001189265pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples