Robustness of global asymptotic stability in indirect field-oriented control of induction motors
dc.contributor.author | Reginatto, Romeu | pt_BR |
dc.contributor.author | Bazanella, Alexandre Sanfelici | pt_BR |
dc.date.accessioned | 2011-01-28T05:59:07Z | pt_BR |
dc.date.issued | 2003 | pt_BR |
dc.identifier.issn | 0018-9286 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/27573 | pt_BR |
dc.description.abstract | The influence of the rotor time constant mismatch on the global stability of induction motors under indirect field oriented control (IFOC) is analyzed. A test for global stability is provided, based on necessary and sufficient conditions for the existence of quadratic Lyapunov functions for IFOC drives. This test yields robustness margins with respect to rotor time constant mismatches.Atypical example is presented to showthat the robustness margins obtained are significantly less conservative than the ones obtained with previously proposed stability criteria. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | IEEE transactions on automatic control. vol. 48, no. 7 (July 2003), p. 1218-1222 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Global asymptotic stability | en |
dc.subject | Motor de indução : Controle | pt_BR |
dc.subject | Microeletrônica | pt_BR |
dc.subject | Indirect field-oriented control (IFOC) | en |
dc.subject | Induction motors | en |
dc.subject | Robustness | en |
dc.title | Robustness of global asymptotic stability in indirect field-oriented control of induction motors | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000435031 | pt_BR |
dc.type.origin | Estrangeiro | pt_BR |
Este item está licenciado na Creative Commons License
-
Artigos de Periódicos (40175)Engenharias (2432)