Mostrar registro simples

dc.contributor.authorVargas, Isadora Martins Postiglioni dept_BR
dc.contributor.authorRodrigues, Luciano Palmeiropt_BR
dc.contributor.authorCandotti, Cláudia Tarragôpt_BR
dc.contributor.authorDias, Alexandre Simõespt_BR
dc.date.accessioned2024-12-04T06:54:57Zpt_BR
dc.date.issued2024pt_BR
dc.identifier.issn2317-0190pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/281980pt_BR
dc.description.abstractLimitações de mobilidade em pacientes pós acidente vascular cerebral (AVC) podem ser avaliadas por escalas, desde que tenham validade e confiabilidade confirmadas. Objetivo:Determinar a validade de conteúdo do Protocolo de utilização da Escala e da Régua de Mobilidade (PERMo) na avaliação da mobilidade do paciente pós AVC, na fase hospitalar. Métodos:Estudo observacional, no qual oito especialistas formaram o comitê de experts que avaliaram o conteúdo do PERMo. Para cada item do PERMo ser válido, todos osíndices de validade de conteúdo (IVCs) deveriam ser >80%. Resultados:Foram necessários quatro roundsde avaliação do PERMo para confirmar sua validade de conteúdo. No terceiro round, apenas um item do PERMoapresentou IVC de 75%, relacionado a capacidade de rolar do paciente. No quarto round, todos os itens do PERMo foram considerados adequados, com IVCs variando de 88% a 100%. Nos quatro rounds, os experts propuseram alterações no PERMo, condizentes com suaavaliação quantitativa, as quais foram todas acatadas pelos pesquisadores. Conclusão:Os adequados IVCs obtidos na versão final do PERMo apontam o consenso entre os experts em entender que o instrumento é valido para a avaliação da mobilidade de pacientespós AVC na fase hospitalar.pt_BR
dc.description.abstractMobility limitations in post-stroke patients can be assessed by scales as long as they have confirmed validity and reliability.Objective: To determine the content validity of a Protocol for Mobility Scale and Mobility Ruler (PERMo) in the mobility assessment of hospitalized patients after stroke. Methods: Validity study, in which a committee of experts with eight participants evaluated the content of the PERMo. For each PERMo item to be valid, all content validity indices (CVIs) should be >80%. Results: After four rounds of content validity evaluation, a final version of the protocol was established. In the third round, only one item related to the patient's ability to roll presented a CVI of 75%. All PERMo items were considered adequate in the fourth round, with CVIs ranging from 88% to 100%. The experts proposed changes in the PERMo throughout the four rounds, consistent with their quantitative assessment. The researchers accepted all of the suggestions.Conclusion: The appropriate CVIs obtained in the final version of the PERMo emphasized a consensus among experts in understanding that the instrument is valid for assessing mobility in hospitalized post-stroke patients.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofActa fisiátrica. São Paulo. Vol. 31, n. 1,(2024), p. 1-8.pt_BR
dc.rightsOpen Accessen
dc.subjectAcidente vascular cerebralpt_BR
dc.subjectStrokeen
dc.subjectGaiten
dc.subjectDestreza motorapt_BR
dc.subjectLimitação da mobilidadept_BR
dc.subjectMotor Skillsen
dc.subjectMobility Limitationen
dc.subjectMarchapt_BR
dc.subjectEstudo de validaçãopt_BR
dc.subjectValidation Studyen
dc.subjectModalidades de fisioterapiapt_BR
dc.subjectPhysical Therapy Modalitiesen
dc.titleValidação de conteúdo do Protocolo de utilização da Escala e Régua de Mobilidade (PERMo) na avaliação da mobilidade do paciente pósacidente vascularcerebral na fase hospitalarpt_BR
dc.title.alternativeContent validation of Mobility Scale and Mobility Ruler (PERMo) in the assessment of mobility for hospitalized patients with stroke en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001208598pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples