Mostrar registro simples

dc.contributor.advisorPartata, Wania Aparecidapt_BR
dc.contributor.authorRocha, Clarice Sperotto dos Santospt_BR
dc.contributor.authorVaz, Marco Aureliopt_BR
dc.date.accessioned2012-11-14T01:42:54Zpt_BR
dc.date.issued2012pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/60963pt_BR
dc.description.abstractO objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho.pt_BR
dc.description.abstractThe goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectElectric stimulation therapyen
dc.subjectTerapia por estimulação elétricapt_BR
dc.subjectInterferential currenten
dc.subjectDorpt_BR
dc.subjectAnalgesiapt_BR
dc.subjectEccentric exerciseen
dc.subjectPainen
dc.subjectExercício físicopt_BR
dc.subjectForça muscularpt_BR
dc.subjectMuscle strengthen
dc.subjectMuscle sorenessen
dc.subjectTraumatismos do joelhopt_BR
dc.subjectCreatine kinaseen
dc.subjectCreatina quinasept_BR
dc.titleEfeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanospt_BR
dc.typeTesept_BR
dc.contributor.advisor-coZaro, Milton Antoniopt_BR
dc.identifier.nrb000862571pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Ciências Básicas da Saúdept_BR
dc.degree.programPrograma de Pós-Graduação em Neurociênciaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2012pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples