Mostrar registro simples

dc.contributor.advisorSanada, Jefferson Tomiopt_BR
dc.contributor.authorSouza, Felippe Bitencourt dept_BR
dc.date.accessioned2017-11-17T02:30:59Zpt_BR
dc.date.issued2017pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/170317pt_BR
dc.description.abstractA confecção de coroas provisórias de resina acrílica ativada quimicamente (RAAQ) faz parte do processo de reabilitação oral com próteses dentárias. Para a confecção destas coroas provisórias são utilizadas diversas técnicas, as quais podem alterar as propriedades da resina, como, por exemplo, rugosidade superficial, dureza e resistência a flexão .Este estudo tem como objetivo avaliar a rugosidade superficial das RAAQs além de, dureza e resistência a flexão, de determinada marca comercial de resina acrílica frente a diferentes técnicas de manipulação. Foram confeccionados corpos de prova utilizando três técnicas diferentes de manipulação de resina acrílica. Os corpos de prova formaram 3 grupos no qual foram analisados: GRUPO I – técnica do pincel; GRUPO II - técnica da mistura conforme fabricante em pote dappen; GRUPO III técnica da mistura conforme fabricante com acréscimo de água. Para cada tipo de processamento foram confeccionados 5 corpos de prova de cada grupo, totalizando 15 corpos de prova para a análise da rugosidade superficial. A rugosidade de superfície (Ra) foi verificada em dois momentos diferentes, antes e após o polimento de superfície. O valor de rugosidade superficial de cada corpo de prova foi determinado pela média aritmética das seis leituras Para a avaliação da resistência a flexão e módulo de elasticidade foram confeccionados 5 corpos de prova para cada grupo, totalizando 15 corpos de prova. Para a análise de microdureza Knoop foram utilizadas as metades que serão fraturadas após o ensaio de resistência á flexão. A partir dos testes realizados foi visto que , no teste da rugosidade superficial o Grupo Água obteve os maiores resultados antes do polimento. Após o polimento observou-se uma melhora significativa em todos grupos quando comparados entre si. Já o teste de resistência a flexão e microdureza mostraram não haver diferenças significativas entre os grupos. Os resultados mostram que para as confecções das coroas provisórias confeccionadas com RAAQS é necessário adequado acabamento e polimento após manipulação da técnica empregada, indiferente da técnica utilizada, sendo o fator polimento o determinante da melhora das resinas. Podemos concluir que o polimento influenciou positivamente na redução da rugosidade superficial, indiferentemente da técnica de confecção empregada, melhorando sua lisura. As técnicas empregadas neste trabalho influenciaram nos valores finais de resistência a flexão e microdureza.pt_BR
dc.description.abstractThe preparation of temporary crowns of chemically active acrylic resin (RAAQ) is part of the oral rehabilitation process with dental prostheses. For the preparation of these temporary crowns, several techniques are used, which can alter the properties of the resin, such as surface roughness, hardness and flexural strength. This study aims to evaluate the surface roughness of RAAQs in addition to hardness and Resistance of a certain trademark of acrylic resin to different manipulation techniques. Test specimens were prepared using three different acrylic resin manipulation techniques. The specimens formed 3 groups in which they were analyzed: GROUP I - brush technique; GROUP II - dappen pot mixing technique; GROUP III mixing technique with water. For each type of processing, 5 test specimens from each group were made, totaling 15 specimens for the analysis of surface roughness. Surface roughness (Ra) was verified at two different times, before and after surface polishing. The surface roughness value of each test specimen was determined by the arithmetic mean of the six readings. For the evaluation of flexural strength and modulus of elasticity, 5 specimens were prepared for each group, totaling 15 specimens. For the Knoop microhardness analysis, the halves were used which will be fractured after the flexural strength test. From the tests carried out, it was observed that, in the surface roughness test, the Water Group obtained the best results before polishing. After polishing, a significant improvement was observed in all groups when compared to each other. The flexural strength and microhardness tests showed no significant differences between groups. The results show that for the confection of temporary crowns made with RAAQS, it is necessary to finish and polish after handling the technique, regardless of the technique used, and the polishing factor is the determinant of resin improvement. We can conclude that the polishing positively influenced the reduction of the surface roughness, regardless of the technique used, improving its smoothness. The techniques employed in this work influenced the final values of flexural strength and microhardness.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectResinas acrílicaspt_BR
dc.subjectChemically Activated Acrylic Resinen
dc.subjectRoughnessen
dc.subjectHardnessen
dc.subjectFlexural Strengthen
dc.titleAvaliação da rugosidade, dureza e resistencia a flexão de resina acrílica ativada quimicamente e manipulada por diversas técnicaspt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb001050790pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.graduationOdontologiapt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples