Mostrar registro simples

dc.contributor.advisorMoraes, Diogo Pompéu dept_BR
dc.contributor.authorAgostini, Maila Noeli Cardosopt_BR
dc.date.accessioned2022-02-01T04:29:26Zpt_BR
dc.date.issued2018pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/234729pt_BR
dc.description.abstractCom o intuito de avaliar metodologias alternativas ao método de preparo de amostras de polietileno (PE) e polipropileno (PP) por decomposição por combustão em sistema aberto, métodos empregando decomposição assistida por radiação micro-ondas foram estudados. Foram avaliados os métodos de decomposição assistida por radiação micro-ondas (MW-AD), decomposição assistida por radiação micro-ondas combinada com radiação ultravioleta (MW-UV) e combustão iniciada por micro-ondas (MIC) para posterior determinação de Mg e Ti. Estes elementos foram determinados empregando espectrometria de emissão óptica com plasma indutivamente acoplado (ICP-OES), espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e espectrometria de absorção atômica com chama (FAAS). O método de MW-AD foi realizado utilizando 5 mL de HNO3 concentrado e 1 mL de HCl concentrado para a decomposição de PE e 3,5 mL de HNO3 concentrado, 0,5 mL de HCl concentrado e 2,5 ml de solução de H2O2 30% para a decomposição de PP. Assim, até 450 mg de polímero foram decompostos e as soluções finais apresentaram teor de carbono residual (RCC) inferior a 6,0%. O estudo do método de MW-UV foi realizado com 250 mg de amostra e duas misturas ácidas foram avaliadas para cada polímero, sendo uma de composição idêntica a utilizada na MW-AD e uma segunda mistura com metade da concentração dos reagentes. As soluções finais apresentaram RCC inferior a 1,5%. No método de MIC uma solução absorvedora de HNO3 4 mol L-1 foi empregada e até 300 mg de polímero foram decompostas. As soluções finais apresentaram RCC inferior a 1,0%. Os três métodos de preparo de amostras foram considerados adequados para a decomposição de polímeros e as soluções finais obtidas foram adequadas para a determinação de Mg e Ti. Foi possível determinar Ti por ICP-OES e ICP-MS e Mg por ICP-OES e FAAS. De acordo com avaliação estatística dos dados obtidos para a determinação dos elementos, os resultados foram concordantes em um nível de confiança de 95%, conforme com o teste t-student empregado para comparar as técnicas de determinação e o teste ANOVA, utilizado para comparar os métodos de decomposição das amostras.pt_BR
dc.description.abstractIn order to evaluate alternative methodologies for the preparation of samples of polyethylene (PE) and polypropylene (PP) by decomposition by open system combustion, methods employing microwave assisted decomposition were studied. The methods of microwave-assisted digestion (MW-AD), microwave-assisted ultraviolet digestion (MW-UV) and microwave-induced combustion (MIC) for further determination of Mg and Ti. These elements were determined using inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) and flame atomic absorption spectrometry (FAAS). The MW-AD method was performed using 5 mL of concentrated HNO3 and 1 mL of concentrated HCl for the PE decomposition and 3.5 mL of concentrated HNO3, 0.5 mL of concentrated HCl and 2.5 ml of 30% H2O2 solution for the PP decomposition. Thus, up to 450 mg of polymer were decomposed and the final solutions had residual carbon content (RCC) of less than 6.0%. The study of the MW-UV method was carried out with 250 mg of sample and using two different acid mixtures for each sample, one of composition identical to that used in the MW-AD and a second mixture with half the concentration of the reagents. The final solutions presented RCC less than 1.5%. In the MIC method using 4 mol L-1 HNO3 as absorbing solution a quantitative recoveries were obtained for Mg and Ti. In addition, it was possible to digest up to 300 mg of polymer. The final solutions presented RCC less than 1.0%. All three methods of sample preparation were considered suitable for the decomposition of polymers and the final solutions obtained were suitable for the determination of Mg and Ti. It was possible to determine Ti by ICP-OES and ICP-MS and Mg by ICP-OES and FAAS. According to a statistical evaluation of the data obtained for the determination of the elements, the results were concordant at a 95% confidence level, according to the t-student test used to compare the determination techniques and the ANOVA test used to compare the methods of decomposition of samples.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectPolyethyleneen
dc.subjectPolietilenopt_BR
dc.subjectPolipropilenopt_BR
dc.subjectPolypropyleneen
dc.subjectRadiação micro-ondaspt_BR
dc.subjectTrace elements determination,en
dc.titleAvaliação de métodos de preparo de amostras de polietileno e polipropileno empregando decomposição assistida por radiação micro-ondas para posterior determinação de magnésio e titâniopt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb001101613pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2018pt_BR
dc.degree.graduationQuímica Industrialpt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples