Objetivo: Comparar os fluxos livres, os calibres e os comprimentos da artéria torácica interna esquerda (ATIE) pediculada (P) e esqueletizada (E) no transoperatório antes e depois da aplicação do vasodilatador tópico (VT). Métodos Em ensaio clínico randomizado e cego foram estudados 50 pacientes submetidos a cirurgia de revascularização miocárdica eletivas quanto ao emprego da ATIE in situ nas formas P ou E. Dos 25 pacientes no grupo pediculada (GP), 16 eram do sexo masculino, apresentando angi ...
Objetivo: Comparar os fluxos livres, os calibres e os comprimentos da artéria torácica interna esquerda (ATIE) pediculada (P) e esqueletizada (E) no transoperatório antes e depois da aplicação do vasodilatador tópico (VT). Métodos Em ensaio clínico randomizado e cego foram estudados 50 pacientes submetidos a cirurgia de revascularização miocárdica eletivas quanto ao emprego da ATIE in situ nas formas P ou E. Dos 25 pacientes no grupo pediculada (GP), 16 eram do sexo masculino, apresentando angina classe II e III (NYHA) e fração de ejeção (FE) de 50,8 ± 9,2%. No grupo esqueletizada (GE), 19 pacientes eram do sexo masculino, possuindo angina classe II e FE de 46,8 ± 9,3%. As medidas foram realizadas pré-circulação extracorpórea e divididas em duas fases: fase 1 (antes) e fase 2 (após 15 min da aplicação da papaverina tópica a 2,5 mg/ml a 37ºC). Durante as aferições, eram monitoradas a pressão arterial média, pressão venosa central e freqüência cardíaca. Resultados O GP apresentou fluxo de 46±16 e 77±28 ml/min e calibre de 1,4±0,1 e 1,7±0,1 mm nas fases 1 e 2, e o GE, 57±27 e 97±35 ml/min de fluxo e 1,4±0,1 e 1,8±0,2 mm de calibre, respectivamente, não havendo diferenças significativas no desfecho comprimento. Conclusão ATIE E demonstrou um aumento significativo no fluxo e calibre, após o uso de VT com p=0,03 e p=0,01 respectivamente, comparados com a ATIE P. ...
Abstract
Objective: To compare the free blood flow, caliber, and length of the left internal thoracic artery (LITA), dissected in the pedicled (P) and skeletonized (S) manners, during surgery before and after topical vasodilator (TV) application. Methods A randomized, blind, clinical trial was carried out with 50 patients undergoing elective myocardial revascularization to assess the use of the LITA in situ in its pedicled or skeletonized form. The 25 patients in the pedicled group (GP) had NYHA class I ...
Objective: To compare the free blood flow, caliber, and length of the left internal thoracic artery (LITA), dissected in the pedicled (P) and skeletonized (S) manners, during surgery before and after topical vasodilator (TV) application. Methods A randomized, blind, clinical trial was carried out with 50 patients undergoing elective myocardial revascularization to assess the use of the LITA in situ in its pedicled or skeletonized form. The 25 patients in the pedicled group (GP) had NYHA class II or III angina, ejection fraction (EF) of 50.8±9.2%, and 16 were of the male sex. The patients in the skeletonized group (SG) had NYHA class II angina, EF of 46.8±9.3%, and 19 were of the male sex. The measurements were performed before extracorporeal circulation and divided into 2 phases: phase 1 (before topical papaverine application) and phase 2 (15 min after topical application of papaverine, 2.5 mg/mL, at 37ºC). During the measurements, mean blood pressure, central venous pressure, and heart rate were monitored. Results The phase 1 and 2 results are as follows: 1) PG: blood flow, 46±16 and 77±28 mL/min; caliber, 1.4±0.1 and 1.7±0.1 mm, respectively; 2) SG: blood flow, 57±27 and 97±35 mL/ min; and caliber, 1.4±0.1 and 1.8±0.2 mm, respectively. No significant differences were observed in length. Conclusion The LITA in SG had a significant increase in blood flow and caliber after the use of TV compared with blood flow and caliber in PG (P=0.03 and P=0.01, respectively). ...