dc.description.abstractCefalogramas posteroanteriores (PA) são importantes ferramentas para o diagnóstico, planejamento e tratamentos ortodônticos, ortopédicos faciais e cirúrgicos. Devido à grande variação nas marcações de pontos cefalométricos há a necessidade de calibração dos examinadores. Este estudo in vitro avaliou comparativamente as medidas cefalométricas realizadas em telerradiografias frontais de crânios secos com e sem identificadores metálicos nos pontos anatômicos de interesse. Para isso foram utilizados 10 crânios secos e realizadas 20 telerradiografias divididas em dois grupos: 10 com (padrão-ouro) e 10 sem identificadores metálicos nos pontos anatômicos. Um avaliador, treinado e calibrado, realizou as marcações dos pontos. A fim de verificar a reprodutibilidade do examinador foi realizado o cálculo do índice de correlação intraclasse em medições realizadas nos crânios sem marcadores. Para verificar diferenças entre as medidas com e sem marcadores foi utilizado o teste estatístico de Bland & Altman. Pode ser observado que houve índices de concordância entre medições consecutivas realizadas pelo mesmo avaliador bastante elevados. Quando estas mesmas medidas são comparadas com o padrão-ouro (com marcadores metálicos) esta concordância não se confirma. Em conclusão, embora marcações realizadas em cefalometrias PA possam ser reprodutíveis elas podem não estar representando os corretos valores do exame e sim, apenas erros métricos sistemáticos.pt_BR
dc.description.abstractPosteroanterior (PA) Cephalograms are important tools for diagnosis, planning and treatments in dentistry. Because of the wide variation in markings of cephalometric points there is the need for calibration of the examiners. This in vitro study evaluated comparatively cephalometric measurements in frontal radiographs of dry skulls with and without metal markers on interest anatomical points. For this, it was used 10 dry skulls and made 20 radiographs divided into two groups: 10 with (gold standard) and 10 without metal markers on anatomical points. A trained and calibrated evaluator made the markings of the points. In order to verify the reproducibility of the examiner was calculated the intraclass correlation coefficient. To verify differences between the measurements with and without markers was used Bland and Altman statistical test. It can be seen that there was high concordance index between consecutive measurements performed by the same examiner. When these same measures are compared with the gold standard this agreement is not confirmed. In conclusion, although markings made in PA cephalometries can be reproducible they may not be representing the correct values of the exam but only systematic metric errors.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectReproducibilityen
dc.subjectCefalometriapt_BR
dc.subjectDiagnóstico por imagempt_BR
dc.subjectCephalometryen
dc.subjectAnatomical pointsen
dc.subjectImaging diagnosisen
dc.titleAvaliação da reprodutibilidade na identificação de pontos anatômicos obtidos em telerradiografias frontais de crânios secos com e sem identificadores metálicospt_BR
dc.typeTrabalho de conclusão de especializaçãopt_BR
dc.identifier.nrb001008467pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.levelespecializaçãopt_BR
dc.degree.specializationCurso de Especialização em Radiologia Odontológica e Imaginologiapt_BR