dc.description.abstractDesde o trágico episódio da Boate Kiss, na cidade de Santa Maria/RS, em Janeiro de 2013, onde centenas de pessoas perderam a vida, constata-se que as ocorrências de incêndios são recorrentes e que as edificações são vulneráveis frente a estes sinistros. A melhor forma de evitar que tragédias similares as da Boate Kiss ocorram, é dotar as edificações, novas ou existentes, de meios que impeçam ou minimizem o risco de incêndio e, caso ocorram, abrandar as suas consequências com as devidas medidas de proteção prescritas nas legislações vigentes. Com relação às edificações existentes, é importante avaliar os riscos e as medidas de proteção nelas inseridas para que se adotem soluções alternativas visando minimizar estes riscos. Para a avaliação de risco de incêndio do Prédio 21107 – Instituto de Psicologia da Universidade Federal do Rio Grande do Sul (UFRGS) utilizou-se o Método de FRAME, largamente adotado e que calcula o risco de incêndio sob o ponto de vista patrimonial, para os seus ocupantes e para as atividades desenvolvidas no seu interior. Neste método, faz-se uma avaliação de vários fatores de influência para obter uma série de valores, o que permite conhecer e tomar decisões sobre o nível de proteção contra incêndio do local avaliado do ponto de vista do perigo de incêndio e para prescrição de medidas de proteção. Na avaliação, esta edificação foi considerada adequada. Porém, considerando a legislação normativa vigente, a edificação necessita de adequações.pt_BR
dc.description.abstractSince the tragic episode at Kiss nightclub, in the city of Santa Maria / RS, in January 2013, where hundreds of people lost their lives, it appears that fires are recurrent and that our buildings are vulnerable to these accidents. The best way to prevent tragedies similar at Kiss nightclub from occurring, is to provide the buildings, new or existing, with means that prevent or minimize the risk of fire and, if they occur, mitigate its consequences with the appropriate protection measures prescribed in current legislation. With regard to existing buildings, it is important to assess the risks and protection measures inserted in them in order to adopt alternative solutions in order to minimize these risks. For the fire risk assessment of Building 21107 - Institute of Psychology of UFRGS, we used the FRAME Method, widely adopted and which calculates the risk of fire from an asset point of view, for its occupants and for the activities carried out inside. . In this method, an evaluation of several influencing factors is made to obtain a series of values, which allows to know and make decisions about the level of fire protection of the evaluated site from the point of view of the fire hazard and for prescription of measures of protection. In the evaluation, this building was considered adequate. However, considering the current regulatory legislation, the building needs adjustments.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEngenharia civilpt_BR
dc.subjectFireen
dc.subjectIncêndiospt_BR
dc.subjectRisken
dc.subjectSegurançapt_BR
dc.subjectEvaluationen
dc.titleAnálise crítica da aplicação do método FRAME para edificação de uso educacional : prédio 21107 - Instituto de Psicologia da UFRGSpt_BR
dc.title.alternativeCritical analysis of the frame method application for educational use building : building 21107 – Psychology Institute of UFRGSen
dc.typeTrabalho de conclusão de especializaçãopt_BR
dc.identifier.nrb001121953pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.levelespecializaçãopt_BR
dc.degree.specializationCurso de Especialização em Engenharia de Segurança Contra Incêndiospt_BR